Laureate™ Duty Cycle Meter

For display of ON or OFF period in percent
Navigation: Home > Timing Product
Duty cycle meter by Laurel Electronics
Key Features
  • Measures ON or OFF period as a percentage of total period.
  • Resolution of 1%, 0.1% or 0.01%.
  • Trigger on positive or negative pulse edges.
  • Frequency from 0.005 Hz to 10 kHz.
  • 6-digit red or green LED display.
  • Isolated 5, 10 or 24 Vdc excitation output to power sensors.
  • NEMA 4X, 1/8 DIN case.
Duty Cycle Mode
Item Displayed
Display Units
Frequency Range
Accuracy
Maximum Timing Interval
ON or OFF duty cycle of periodic pulse waveshape
1%, 0.1%, 0.01%
0.005 Hz to 10 kHz
0.01%, 0.005 Hz to 500 Hz, 0.1% at 5 kHz, 1% at 10 kHz
199.99 s
Display
Readout
Range
Indicators
6 LED digits, 7-segment, 14.2 mm (.56"), red or green
-999999 to +999999
Four LED lamps
Inputs
Types

Signal Ground
Minimum Signal
Maximum Signal
Maximum Frequency
Contact Debounce
AC, pulses from NPN, PNP transistors, contact closures,
magnetic pickups.
Common ground for channels A & B.
Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V)
250 Vac
1 MHz, 30 kHz, 250 Hz (selectable)
0, 3, 50 ms (selectable)
Update Rate
Conversion Interval
Gate Time
Time Before Zero Output
Gate time + 30 ms + 0-2 signal periods
Selectable 10 ms to 199.99 s
Selectable 10 ms to 199.99 s
Power
Voltage, standard
Voltage, optional
Frequency
Power Isolation
85-264 Vac or 90-300 Vdc (DC operation not UL approved)
12-32 Vac or 10-48 Vdc
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
Analog Output (optional)
Output Levels
Current compliance
Voltage compliance
Scaling
Resolution
Isolation
4-20 mA, 0-20 mA, 0-10V, -10 to +10V (jumper selectable)
2 mA at 10V ( > 5 kΩ load)
12V at 20 mA ( < 600Ω load)
Zero and full scale adjustable from -99999 to +99999
16 bits (0.0015% of full scale)
250V rms working, 2.3 kV rms per 1 min test
Relay Outputs (optional)
Relay Types

Current Ratings

Output common
Isolation
2 Form C contact relays or 4 Form A contact relays (NO)
2 or 4 Form A, AC/DC solid state relays (NO)
8A at 250 Vac or 24 Vdc for contact relays
130 mA at 140 Vac or 180 Vdc for solid state relays
Isolated commons for dual relays or each pair of quad relays
250V rms working, 2.3 kV rms per 1 min test
Serial Data I/O (optional)
Board Selections

Protocols
Data Rates
Digital Addresses
Isolation
Ethernet, Ethernet-to-RS485 server, USB, USB-to-RS485 server, RS485 (dual RJ11), RS485 Modbus (dual RJ45), RS232
Modbus RTU, Modbus ASCII, Laurel ASCII protocol
300 to 19200 baud
247 (Modbus), 31 (Laurel ASCII),
250V rms working, 2.3 kV rms per 1 min test
Environmental
Operating Temp.
Storage Temp.
Relative Humidity
Protection
0°C to 60°C
-40°C to 85°C
95% at 40°C, non-condensing
NEMA-4X (IP-65) when panel mounted
Signal Connections
Duty Cycle Flow Graph
feedback