Laureate ™ Load Cell & Microvolt
Digital Panel Meter
20 mV - 500 mV full-scale ranges, 4- or 6-wire connection
Key Features
- 20, 50, 100, 250 & 500 mV ranges
- 5-digit resolution with span from 0 to ±99,999
- Zero from -99,999 to +99,999
- Selectable fixed right-hand zero with rounding
- Isolated 10 Vdc supply to power up to four 350-ohm load cells in parallel
- 4- or 6-wire hookup to avoid lead resistance effects
Sample Load Cell Meter Applications
 |
Auto-Tare
To read the net weight of an object, the empty container is first weighed, and an external button is pushed to zero out the display. The meter will then read net weight when an object is added to the empty container. The tare value is stored in memory for subsequent readings.
|
 | Determining Volume Using Load Cells
An easy way to determine volume of an irregularly shaped tank with no need for linearizing is to weigh the tank using load cells. The meter will automatic- ally tare out the weight of the empty tank and then scale the load cell signals to units of volume, such as gallons. |
 | Capture for Tensile Strength of Wire