| Signal |
Range
Input resistance
Bias current
Max input
NMR, 45 to 1000 Hz
CMR, 0 to 450 Hz |
4-20 mA
22Ω
N/A
80 mA
56 dB
70 dB |
0-10 V
1 MΩ
5 pA
100 V
56 dB
70 dB |
| Display |
Format
Scale length |
50 red LED segments
250 mm (9.84") |
| Accuracy |
Resolution
Accuracy at 25÷C
Speed of response
Warm-up time
Calibration |
1 part in 50
± 0.5% of full scale
100 msec
None required
Zero & span potentiometers |
| Power Supply |
Resolution
Accuracy at 25÷C
Speed of response
Warm-up time
Calibration |
1 part in 50
± 0.5% of full scale
100 msec
None required
Zero & span potentiometers |
| Environmental |
Operating
Temperature
Storage Temperature
Relative Humidity
Corrosion resistance
Protection |
-20°C to
50°C (4°F to 122°F)
-40°C to 85°C (-40°F
to 185°F)
0-90% RH at 40°C, non-condensing
Avoid chemicals harmful polycarbonate