Laureate™ Serially Driven 6-Digit Panel Meter & Remote Display
With optional analog output & setpoint control output capabilities
Key Features
- 6-digit numeric display of received serial data
- Same appearance as 1/8 DIN Laureate instruments
- Works in slave mode
- User selectable protocol : Modbus RTU or ASCII, Laurel ASCII
- Universal AC power, 85-264 Vac
- NEMA 4X, 1/8 DIN case
| Display |
Readout
Range
Indicators |
6 LED digits, 7-segment, 14.2 mm (.56"), red or green
-999999 to +999999
Four LED lamps |
| Power |
Voltage, standard
Voltage, optional
Frequency
Power Isolation
|
85-264 Vac or 90-300 Vdc (DC operation not UL approved)
12-32 Vac or 10-48 Vdc
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
|
| Serial Interface (one required) |
Board Selections
Protocols
Data Rates
Digital Addresses
Isolation |
Ethernet, Ethernet-to-RS485 converter, USB, USB-to-RS485 converter,
RS485(dual RJ11), RS485 Modbus (dual RJ45), RS232.
Modbus RTU, Modbus ASCII, Laurel ASCII protocol
300 to 19200 baud
247 (Modbus), 31 (Laurel ASCII),
250V rms working, 2.3 kV rms per 1 min test
|
| Analog Output (optional) |
Output Levels
Current compliance
Voltage compliance
Scaling
Resolution
Isolation
|
4-20 mA, 0-20 mA, 0-10V, -10 to +10V (single-output option)
2 mA at 10V ( > 5 kΩ load)
12V at 20 mA ( < 600Ω load)
Zero and full scale adjustable from -99999 to +99999
16 bits (0.0015% of full scale)
250V rms working, 2.3 kV rms per 1 min test
(dual analog outputs share the same ground)
|
| Relay Outputs (optional) |
Relay Types
Current Ratings
Output common
Isolation |
2 Form C contact relays or 4 Form A contact relays (NO)
2 or 4 Form A, AC/DC solid state relays (NO)
8A at 250 Vac or 24 Vdc for contact relays
130 mA at 140 Vac or 180 Vdc for solid state relays
Isolated commons for dual relays or each pair of quad relays
250V rms working, 2.3 kV rms per 1 min test |
| Environmental |
Operating Temp.
Storage Temp.
Relative Humidity
Protection |
0°C to 60°C
-40°C to 85°C
95% at 40°C, non-condensing
NEMA-4X (IP-65) when panel mounted |
| Displayable Parameters when Connected to a Laureate Counter |
FR (Frequency)
Sig Conditioner,
Extended |
Item #1: Rate A, total A, time interval, period A
Item #2: Rate B, total B, period B
Item #3: Peak
Item #4: Valley |
FR (Frequency)
Sig Conditioner,
Extended |
Item #1: Rate A, total A, rate B, total B, time interval, phase, A+B, A-B, AxB, A/B, A/B-1, batch total, stopwatch.
Item #2: Rate A, total A, rate B, total B, period B, batch grand total, number of batches, accumulated time.
Item #3: Rate B, total B, rate derived from batch, period B.
Item #4: Peak or valley |
VF (V-to-F)
Sig Conditioner,
Extended |
Item #1: Rate, total, batch total.
Item #2: Rate, total, batch grand total, number of batches.
Item #3: Batch rate
Item #4: Peak or valley |
|