4-20 mA Current Output Transmitter for DC Voltage or Current Input
DIN Rail mounted, digitally programmable.
Exceptional accuracy at high update rates.
Standard Features
- ±0.2, ±2, ±20, ±200, ±300V & ±600V voltage input ranges
- ±2, ±20, ±200 mA & ±5A current input ranges
- All input ranges user selectable & factory calibrated
- 4-20 mA, 0-20 mA or 0-10V transmitter output, isolated.
- Output resolution: 0.0015% of span (16 bits)
- Output accuracy: ±0.02% of span
- Detachable screw-clamp connectors
- 5V, 10V or 24V dc transducer excitation output, isolated
- Dual solid state relays for alarm or control, isolated
- RS232 or RS485 serial communications, isolated
- Universal AC power, 85-264 Vac
- Optional low voltage power, 10-48 Vdc or 12-32 Vac
- Extended main board for custom curve linearization & rate from successive readings.
Specifications
Laureate 4-20 mA Transmitter for DC Voltage or Current Input
| Analog Input |
Range |
Resolution |
Accuracy |
Input Ohms |
| DC Voltage |
200.00 mV
2.0000 V
20.000 V
200.00 V
600.0 V |
10 µV
100 µV
1 mV
10 mV
100 mV |
±0.01% FS
± 2 counts |
1 GΩ
1 MΩ
1 MΩ
1 MΩ
1 MΩ |
| DC Current |
2.0000 mA
20.000 mA
200.00 mA |
0.1 µA
1 µA
10 µA |
±0.01% FS
± 2 counts |
100 Ω
10 Ω
1 Ω
|
| 5.000 A |
1 mA |
±0.1% FS
± 2 counts |
0.01 Ω |
Input Resolution
Update Rate, Max
Max applied voltage
Over-current protection |
16 bits (65,536 steps)
50/sec at 50 Hz, 60/sec at 60 Hz
600 Vac for 20, 200 & 600 V ranges, 125 Vac other ranges
25x for 2 mA, 8x for 20 mA, 2.5x for 200 mA, 1x for 5 A |
| Analog Output (standard) |
Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Isolation |
0-20 mA or 0-10 Vdc (selectable)
10V ( 0-500 Ω load )
2 mA ( 5 kΩ load )
16 bits (65,536 steps)
0.02% of output span plus conversion accuracy
250V rms working, 2.3 kV rms per 1 minute test |
| Dual Relay Output (standard) |
Relay Type
Load Rating |
Two solid state relays, SPST, normally open, Form A
130 mA at 140 Vac or 180 Vdc |
| Transducer Excitation Output (standard) |
Output Levels
Output Isolation |
5V@100 mA, 10V@120 mA, 24V@50 mA (jumper selectable)
50V from signal ground |
| Serial Data Output (standard) |
Signal Types
Data Rates
Output Isolation
Serial Protocols
Modbus Modes
Modbus Compliance
Digital Addressing |
RS232 or RS485 (half or full duplex)
300, 600, 1200, 2400, 4800, 9600, 19200 baud
250V rms working, 2.3 kV rms per 1 min test
Modbus RTU, Modbus ASCII, Laurel ASCII
RTU or ASCII
Modbus over Serial Line Specification V1.0 (2002)
247 Modbus addresses.
Up to 32 devices on an RS485 line w/o a repeater. |
| Power Input |
Standard Power
Low Power Option
Power Frequency
Power Isolation
Power Consumption |
85-264 Vac or 90-300 Vdc (DC operation not UL approved)
10-48 Vdc or 12-32 Vac
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
2W typical, 3W with max excitation output |
| Mechanical |
Dimensions
Mounting
Electrical Connections |
129 x 104 x 22.5 mm case
35 mm rail per DIN EN 50022
Plug-in screw-clamp connectors |
| Environmental |
Operating Temperature
Storage Temperature
Relative Humidity
Cooling Required |
0°C to 55°C
-40°C to 85°C
95% at 40°C, non-condensing
Mount transmitters with ventilation holes at top and bottom.
Leave 6 mm (1/4") between transmitters, or force air with a fan. |
Pinout Laureate 4-20 mA Transmitter for DC Voltage or Current Input
|