4-20 mA Current Output Transmitter for Duty Cycle Input

Transmits ON or OFF period in percent of total period. DIN Rail mounted, digitally programmable.
Navigation:  Home > Transmitters, 4-20 mA
4-20 mA current transmitter, duty cycle input
Key Features
  • Transmits On or Off period as a percentage of total period
  • Frequencies from 0.005 Hz to 10 kHz
  • Inputs from NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups down to 12 mV, or AC inputs up to 250 Vac.
  • Triggers on positive or negative pulse edges
  • DIN rail mount housing only 22.5 mm wide
  • Plug-in screw-clamp connectors
  • 5V, 10V or 24V dc sensor excitation output, isolated
  • Dual solid state relays for alarm or control, isolated
  • Isolated 4-20 mA or 0-10V transmitter output, selectable
  • RS232 or RS485 serial communications, isolated
  • Universal AC power, 85-264 Vac
  • Optional ow voltage power, 10-48 Vdc or 12-32 Vac
  • Easy setup with PC-based Instrument Setup Software
Duty Cycle Mode
Item Transmitted
Transmitted Percentage
Frequency Range
Input Accuracy
ON or OFF duty cycle of periodic pulse waveshapes
0% to 100%
0.005 Hz to 50 kHz
0.01%, 0.005 Hz to 500 Hz; 0.1% at 5 kHz; 1% at 50 kHz
Update Rate
Conversion Interval
Gate Time
Time Before Zero Output
Gate time + 30 ms + 0-2 signal periods
Selectable 10 ms to 199.99 s
Selectable 10 ms to 199.99 s
Pulse Input
Types

Grounding
Minimum Signal
Maximum Signal
Noise Filter
Contact Debounce
AC, pulses from NPN, PNP transistors, contact closures,
magnetic pickups
Common ground for channels A & B.
Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V)
250 Vac
1 MHz, 30 kHz, 250 Hz (selectable)
0, 3, 50 ms (selectable)
Analog Output
Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Isolation
0-20 mA or  0-10 Vdc (selectable)
10V ( 0-500 ohm load )
2 mA ( 5 kOhm load )
16 bits (65,536 steps)
0.02% of output span plus conversion accuracy
250V rms working, 2.3 kV rms per 1 minute test
Sensor Excitation Output (standard)
Output Levels
Output Isolation
5V@100 mA, 10V@120 mA, 24V@50 mA (jumper selectable)
50V from signal ground
Dual Relay Output (standard)
Relay Type
Load Rating
Two solid state relays, SPST, normally open, Form A
130 mA at 140 Vac or 180 Vdc
Serial Communications (standard)
Signal Types
Data Rates
Output Isolation
Serial Protocols
Modbus Modes
Modbus Compliance
Digital Addressing
RS232 or RS485 (half or full duplex)
300, 600, 1200, 2400, 4800, 9600, 19200 baud
250V rms working, 2.3 kV rms per 1 min test
Modbus RTU, Modbus ASCII, Laurel ASCII
RTU or ASCII
Modbus over Serial Line Specification V1.0 (2002)
247 Modbus addresses.
Up to 32 devices on an RS485 line w/o a repeater.
Power Input
Standard Power
Low Power Option
Power Frequency
Power Isolation
Power Consumption
85-264 Vac or 90-300 Vdc (DC operation not UL approved)
10-48 Vdc or 12-32 Vac
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
2W typical, 3W with max excitation output
Mechanical
Dimensions
Mounting
Electrical Connections
129 x 104 x 22.5 mm case
35 mm rail per DIN EN 50022
Plug-in screw-clamp connectors
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
Cooling Required
0°C to 55°C
-40°C to 85°C
95% at 40°C, non-condensing
Mount transmitters with ventilation holes at top and bottom.
Leave 6 mm (1/4") between transmitters, or force air with a fan.
Pinout

Laureate 4-20 mA Transmitter for Duty Cycle Input


feedback