Key Features
  • Transmits single event time or accumulated time of all events
  • Timing from 0.2 µs to 999,999 hrs
  • Inputs from NPN or PNP proximity switches, contact closures, digital logic, or magnetic pickups down to 12 mV.
  • Isolated 4-20 mA or 0-10V transmitter output, selectable
  • Output resolution: 0.0015% of span (16 bits)
  • Output accuracy: ±0.02% of span
  • DIN rail mount housing only 22.5 mm wide
  • Plug-in screw-clamp connectors
  • 5V, 10V or 24V dc sensor excitation output, isolated
  • Dual solid state relays for alarm or control, isolated
  • RS232 or RS485 serial communications, isolated
  • Universal AC power, 85-264 Vac
  • Optional low voltage power, 10-48 Vdc or 12-32 Vac
  • Easy setup with PC-based Instrument Setup Software
Pulse Input
Types

Signal Ground
Minimum Signal
Maximum Signal
Maximum Frequency
Contact Debounce
Time Base Accuracy
Span Tempco
Long-term Drift
AC, pulses from NPN, PNP transistors, contact closures,
magnetic pickups.
Common ground for channels A & B.
Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V).
250 Vac
1 MHz, 30 kHz, 250 Hz (selectable).
0, 3, 50 ms (selectable).
Quartz crystal calibrated to ±2 ppm.
±1 ppm/°C (typ)
±5 ppm/year
Stopwatch Operation
Timing Modes:
   With CH A only
   With CH A tied to CH B
   With CH A and CH B

Timing Interval
Timing Resolution
Selectable Decimal Time
Selectable Clock Time
Output Update Rate

+ to + edge, or - to - edge.
+ to - edge, or - to + edge.
+ edge of A to + edge of B, + edge of A to - edge of B,
- edge to A to - edge of B, - edge of A to - edge of B
1 µs to 999,999 hrs
0.2 µs to 1 hr
999999 H, M or S format with decimal point
HH.MM.SS format
Programmable gate time from 10 ms to 199.99 s + 30 ms
Analog Output (standard)
Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Update Rate
Output Isolation
4-20 mA and 0-10 Vdc (selectable)
10V ( 0-500 ohm load )
2 mA ( 5 kOhm load )
16 bits (65,536 steps)
±0.02% of output span
Programmed gate time + 30 ms + 0-2 signal periods
250V rms working, 2.3 kV rms per 1 minute test
Sensor Excitation Output (standard)
Output Levels
Output Isolation
5V@100 mA, 10V@120 mA, 24V@50 mA (jumper selectable)
50V from signal ground
Dual Relay Output (standard)
Relay Type
Load Rating
Two solid state relays, SPST, normally open, Form A
130 mA at 140 Vac or 180 Vdc
Serial Communications (standard)
Signal Types
Data Rates
Output Isolation
Serial Protocols
Modbus Modes
Modbus Compliance
Digital Addressing
RS232 or RS485 (half or full duplex)
300, 600, 1200, 2400, 4800, 9600, 19200 baud
250V rms working, 2.3 kV rms per 1 min test
Modbus RTU, Modbus ASCII, Laurel ASCII
RTU or ASCII
Modbus over Serial Line Specification V1.0 (2002)
247 Modbus addresses.
Up to 32 devices on an RS485 line w/o a repeater.
Power Input
Standard Power
Low Power Option
Power Frequency
Power Isolation
Power Consumption
85-264 Vac or 90-300 Vdc (DC operation not UL approved)
10-48 Vdc or 12-32 Vac
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
2W typical, 3W with max excitation output
Mechanical
Dimensions
Mounting
Electrical Connections
129 x 104 x 22.5 mm case
35 mm rail per DIN EN 50022
Plug-in screw-clamp connectors
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
Cooling Required
0°C to 55°C
-40°C to 85°C
95% at 40°C, non-condensing
Mount transmitters with ventilation holes at top and bottom.
Leave 6 mm (1/4") between transmitters, or force air with a fan.
Pinout

Laureate 4-20 mA Transmitter for Time of Single or Accumulated Events