4-20 mA Current Output Transmitter for Stopwatch Time of Single or Accumulated Events
Resolution to 0.2 µs. Duration to 999,999 hrs.
DIN Rail mounted, digitally programmable.
Key Features
- Transmits single event time or accumulated time of all events
- Timing from 0.2 µs to 999,999 hrs
- Inputs from NPN or PNP proximity switches, contact closures, digital logic, or magnetic pickups down to 12 mV.
- Isolated 4-20 mA or 0-10V transmitter output, selectable
- Output resolution: 0.0015% of span (16 bits)
- Output accuracy: ±0.02% of span
- DIN rail mount housing only 22.5 mm wide
- Plug-in screw-clamp connectors
- 5V, 10V or 24V dc sensor excitation output, isolated
- Dual solid state relays for alarm or control, isolated
- RS232 or RS485 serial communications, isolated
- Universal AC power, 85-264 Vac
- Optional low voltage power, 10-48 Vdc or 12-32 Vac
- Easy setup with PC-based Instrument Setup Software
| Pulse Input |
Types
Signal Ground
Minimum Signal
Maximum Signal
Maximum Frequency
Contact Debounce
Time Base Accuracy
Span Tempco
Long-term Drift |
AC, pulses from NPN, PNP transistors, contact closures,
magnetic pickups.
Common ground for channels A & B.
Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V).
250 Vac
1 MHz, 30 kHz, 250 Hz (selectable).
0, 3, 50 ms (selectable).
Quartz crystal calibrated to ±2 ppm.
±1 ppm/°C (typ)
±5 ppm/year |
| Stopwatch Operation |
Timing Modes:
With CH A only
With CH A tied to CH B
With CH A and CH B
Timing Interval
Timing Resolution
Selectable Decimal Time
Selectable Clock Time
Output Update Rate |
+ to + edge, or - to - edge.
+ to - edge, or - to + edge.
+ edge of A to + edge of B, + edge of A to - edge of B,
- edge to A to - edge of B, - edge of A to - edge of B
1 µs to 999,999 hrs
0.2 µs to 1 hr
999999 H, M or S format with decimal point
HH.MM.SS format
Programmable gate time from 10 ms to 199.99 s + 30 ms |
| Analog Output (standard) |
Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Update Rate
Output Isolation |
4-20 mA and 0-10 Vdc (selectable)
10V ( 0-500 ohm load )
2 mA ( 5 kOhm load )
16 bits (65,536 steps)
±0.02% of output span
Programmed gate time + 30 ms + 0-2 signal periods
250V rms working, 2.3 kV rms per 1 minute test |
| Sensor Excitation Output (standard) |
Output Levels
Output Isolation |
5V@100 mA, 10V@120 mA, 24V@50 mA (jumper selectable)
50V from signal ground |
| Dual Relay Output (standard) |
Relay Type
Load Rating |
Two solid state relays, SPST, normally open, Form A
130 mA at 140 Vac or 180 Vdc |
| Serial Communications (standard) |
Signal Types
Data Rates
Output Isolation
Serial Protocols
Modbus Modes
Modbus Compliance
Digital Addressing
|
RS232 or RS485 (half or full duplex)
300, 600, 1200, 2400, 4800, 9600, 19200 baud
250V rms working, 2.3 kV rms per 1 min test
Modbus RTU, Modbus ASCII, Laurel ASCII
RTU or ASCII
Modbus over Serial Line Specification V1.0 (2002)
247 Modbus addresses.
Up to 32 devices on an RS485 line w/o a repeater. |
| Power Input |
Standard Power
Low Power Option
Power Frequency
Power Isolation
Power Consumption |
85-264 Vac or 90-300 Vdc (DC operation not UL approved)
10-48 Vdc or 12-32 Vac
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
2W typical, 3W with max excitation output |
| Mechanical |
Dimensions
Mounting
Electrical Connections |
129 x 104 x 22.5 mm case
35 mm rail per DIN EN 50022
Plug-in screw-clamp connectors |
| Environmental |
Operating Temperature
Storage Temperature
Relative Humidity
Cooling Required |
0°C to 55°C
-40°C to 85°C
95% at 40°C, non-condensing
Mount transmitters with ventilation holes at top and bottom.
Leave 6 mm (1/4") between transmitters, or force air with a fan. |
Pinout
Laureate 4-20 mA Transmitter for Time of Single or Accumulated Events
|