4-20 mA Current Output Transmitter & Dual Pulse Input Totalizer
Rate or total in same transmitter, square root extraction.
DIN Rail mounted, digitally programmable.
Key Features
- Isolated 4-20 mA or 0-10V transmitter outputs, selectable
- Two independently field-scalable pulse input channels
- Pulse input rates to 1 MHz
- Up counting from zero to preset value using positive scale factor
- Down counting from preset to zero using negative scale factor
- Output resolution: 0.0015% of span (16 bits)
- 5V, 10V or 24V dc sensor excitation output, isolated
- Dual solid state relays for alarm or control, isolated
- RS232 or RS485 serial communications, isolated
Specifications
Laureate 4-20 mA Transmitter with Dual PulseTotalizing Inputs
| Pulse Input |
Types
Signal Ground
Minimum Signal
Maximum Signal
Maximum Frequency
Contact Debounce |
AC, pulses from NPN, PNP transistors, contact closures,
magnetic pickups.
Common ground for channels A & B.
Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V).
250 Vac
1 MHz, 30 kHz, 250 Hz (selectable).
0, 3, 50 ms (selectable). |
| Analog Output (standard) |
Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Update Rate
Output Isolation |
4-20 mA and 0-10 Vdc (selectable)
10V ( 0-500 Ω load )
2 mA ( 5 kΩ load )
16 bits (65,536 steps)
0.02% of output span
Programmed gate time + 30 ms + 0-2 signal periods
250V rms working, 2.3 kV rms per 1 minute test |
| Transducer Excitation Output (standard) |
Jumper Selection 1
Jumper Selection 2
Jumper Selection 3 |
10V @ 60 mA, isolated to 50V from signal ground
5V @ 50 mA, isolated to 50V from signal ground
15V @ 60 mA, non-isolated |
| Dual Relay Output (optional) |
Relay Type
Load Rating |
Two solid state relays, SPST, normally open, Form A
130 mA at 140 Vac or 180 Vdc |
| Power Input |
Standard Power
Low Power Option
Power Frequency
Power Isolation
Power Consumption |
85-264 Vac or 90-300 Vdc (DC operation not UL approved)
10-48 Vdc or 12-32 Vac
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
2W typical, 3W with max excitation output |
| Mechanical |
Dimensions
Mounting
Electrical Connections |
129 x 104 x 22.5 mm case
35 mm rail per DIN EN 50022
Plug-in screw-clamp connectors |
| Environmental |
Operating Temperature
Storage Temperature
Relative Humidity
Cooling Required |
0°C to 55°C
-40°C to 85°C
95% at 40°C, non-condensing
Mount transmitters with ventilation holes at top and bottom.
Leave 6 mm (1/4") between transmitters, or force air with a fan. |
Application Examples of Totalizing Meters & Transmitters
| Up/Down Totalizing |
 |
Up/down totalizing is provided by a mode of the Extended totalizing transmitter where pulses are either added or subtracted on Channel A based on a direction input on Channel B. The unit can also be programmed so that counting by Channel A is inhibited by an input on Channel B. |
| Combining Two Totals |
 |
A+B, A-B, A/B and AxB arithmetic functions are available with the Extended totalizing transmitter. A+B can sum two totals, while A-B subtracts the outflow total from inflow total. A/B ratio applied to two totals helps assure the proper mixing of components. |
| Up or Down Counting with Preset |
 |
A single Laureate dual-channel totalizing transmitter will handle two repetitive fill operations by counting from zero up to a preset, or down from a preset to zero. The dual relay option is required. |
| Machine ON Time and Utilization |
 |
An easy way to measure the ON time of machines is to count AC line cycles and scale the total to hours. To display machine utilization or duty cycle in percent, use the Extended totalizing transmitter. Connect Channel A to switched AC and Channel B to the AC line, and apply a 100 multiplier to the A/B ratio. |
| Custom Curve Linearization |
 | The Extended version of the Laureate dual channel totalizing transmitter can transmit scaled rate or total for the same channel at the push of a button, and alarm both the rate and total. The Extended version can also do curve linearization, thereby extending the working range and accuracy of flow transducers. |
Pinout