Modbus & Serial Output Transmitter for Frequency, Rate or Period

Dual channels. Rate and total in same transmitter. DIN Rail mounted, digitally programmable.
Navigation: Home > Modbus transmitters
Serial ASCII or Modbus Transmitter, Frequency, Rate or Period Input
Key Features
  • Selectable Modbus or Laurel ASCII protocol
  • Selectable "count by" of 10 or 100 with rounding
  • Line frequency measurement to 60.0000 in a few line cycles
  • Square root extraction standard
  • DIN rail mount housing only 22.5 mm wide
  • 5V, 10V or 24V dc sensor excitation output, isolated
  • Dual solid state relays for alarm or control, isolated
  • 0-10V, 4-20 mA or 0-20 mA transmitter output, isolated
  • Universal AC power, 85-264 Vac
  • Priced at only $235 (basic pulse input transmitter)
Application Examples of Frequency / Rate Meters
AC Line Frequency
AC Line Frequency Meter or Transmitter Laureate frequency meters and transmitters accept line voltages up to 250 Vac and output line frequency to 6-digit accuracy (50.0000 or 60.0000) in a few line cycles. Fast low frequency response is achieved by timing the period and taking its inverse.
RPM and Speed
Tachometer and Pulse Input Rate Meter or Transmitter Laureate frequency meters and transmitters can sense low-level signals from magnetic pickups or the NPN or PNP transistor output of active sensors. These can be powered directly by the meter or transmitter. Output in RPM or units of speed is achieved by mathematical scaling.
Flow Rate and Simultaneous Total
Simultaneous Rate Meter and Totalizer Mode of Frequency Meter or Transmitter Laureate frequency meters andtransmitters are compatible with all flow meters which generate pulses at a frequency proportional to flow rate. The Extended version can display scaled rate or total for the same input at the push of a button, and alarm from both the rate and total.
Combining Two Rates
Dual Pulse Input Rate Meter or Transmitter to Combine Two Rates Extended Laureate frequency meters and transmitters offer A+B, A-B and A/B arithmetic functions. A+B allows two input flows to be summed for total flow, while A-B allows outflow to be subtracted from inflow for net flow. Flow ratios aid in the proper mixing of ingredients.
Custom Curve Linearization
Custom Curve Linearization for Laureate Rate Meters and Transmitters Extended Laureate frequency meters and transmitters can linearize the output turbine flow meters, which tend to be nonlinear on the low end. Linearizing improves the dynamic range and accuracy of turbine flow meters.
System-level Capabilities
Laureate dual-channel rate meters and transmitters can independently scale, display and alarm two pulse input channels. All signal or alarm data can further be transmitted via RS-232 or RS-485, including peak readings and arithmetic combinations of the two rates. System Interfaces of Laureate Frequency Meters, Rate Meters and Transmitters