LTS6 Serial-to-Analog DIN Rail Transmitter

Converts serial input data to a scaled analog output signal.
Navigation:  Home > 4-20 mA Transmitters
Laurel TS6 Serial-to-Analog DIN Rail Transmitter
Standard Features
  • Converts serial input data to a scaled analog output signal.
  • Operates in slave mode with RS-232 or RS-485 serial data input
  • Four protocols: Modbus RTU, Modbus ASCII, Laurel ASCII, ASCII characters
  • Able to retrieve data from long character strings
  • Data rates from 300 to 19,200 bps
  • Isolated 4-20 mA, 0-20 mA, or 0-10V transmitter output, user selectable
  • Output resolution: 0.0015% of span (16 bits), accuracy : ±0.02% of span
  • Update rate to 60/sec
  • Detachable screw-clamp connectors
  • Easy setup with PC-based Instrument Setup Software
  • Dual solid state relays for alarm or control, isolated
  • Universal AC power, 85-264 Vac
Options
  • Low voltage power, 10-48 Vdc or 12-32 Vac

Laureate LTS6 Serial Input, Analog Output, DIN Rail Transmitter

Serial Communications (standard)
Signal Types
Data Rates
Output Isolation
Serial Protocols
Modbus Modes
Modbus Compliance
Digital Addressing
RS232 or RS485 (half or full duplex)
300, 600, 1200, 2400, 4800, 9600, 19200 baud
250V rms working, 2.3 kV rms per 1 min test
Modbus RTU, Modbus ASCII, Laurel ASCII
RTU or ASCII
Modbus over Serial Line Specification V1.0 (2002)
247 Modbus addresses.
Up to 32 devices on an RS485 line without a repeater.
Analog Output (standard)
Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Update Rate
Output Isolation
4-20 mA, 0-20 mA, 0-10 Vdc (selectable)
10V ( 0-500Ω load )
2 mA ( 5 kΩ load )
16 bits (65,536 steps)
0.02% of output span
Determined by input data rate
250V rms working, 2.3 kV rms per 1 minute test
Dual Relay Output (standard)
Relay Type
Load Rating
Two solid state relays, SPST, normally open, Form A
130 mA at 140 Vac or 180 Vdc
Power Input
Standard Power
Low Power Option
Power Frequency
Power Isolation
Power Consumption
85-264 Vac or 90-300 Vdc (DC operation not UL approved)
10-48 Vdc or 12-32 Vac
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
2W typical, 3W with max excitation output
Mechanical
Dimensions
Mounting
Electrical Connections
129 x 104 x 22.5 mm case
35 mm rail per DIN EN 50022
Plug-in screw-clamp connectors
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
Cooling Required
0°C to 55°C
-40°C to 85°C
95% at 40°C, non-condensing
Mount transmitters with ventilation holes at top and bottom.
Leave 6 mm (1/4") between transmitters, or force air with a fan.

 

Pinout

Laureate LTS6 Serial Input, Analog Output, DIN Rail Transmitter